Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Viruses ; 12(6)2020 06 25.
Artigo em Inglês | MEDLINE | ID: covidwho-1726024

RESUMO

The recent emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) worldwide has highlighted the importance of reliable and rapid diagnostic testing to prevent and control virus circulation. Dozens of monoplex in-house RT-qPCR assays are already available; however, the development of dual-target assays is suited to avoid false-negative results caused by polymorphisms or point mutations, that can compromise the accuracy of diagnostic and screening tests. In this study, two mono-target assays recommended by WHO (E-Sarbeco (enveloppe gene, Charite University, Berlin, Germany) and RdRp-IP4 (RdRp, Institut Pasteur, Paris, France)) were selected and combined in a unique robust test; the resulting duo SARS-CoV-2 RT-qPCR assay was compared to the two parental monoplex tests. The duo SARS-CoV-2 assay performed equally, or better, in terms of sensitivity, specificity, linearity and signal intensity. We demonstrated that combining two single systems into a dual-target assay (with or without an MS2-based internal control) did not impair performances, providing a potent tool adapted for routine molecular diagnosis in clinical microbiology laboratories.


Assuntos
Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , RNA Polimerase Dependente de RNA/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Proteínas do Envelope Viral/genética , Proteínas não Estruturais Virais/genética , Betacoronavirus/genética , COVID-19 , Proteínas do Envelope de Coronavírus , Infecções por Coronavirus/virologia , RNA-Polimerase RNA-Dependente de Coronavírus , Humanos , Pandemias , Pneumonia Viral/virologia , RNA Viral/análise , SARS-CoV-2 , Sensibilidade e Especificidade , Organização Mundial da Saúde
2.
Euro Surveill ; 26(41)2021 10.
Artigo em Inglês | MEDLINE | ID: covidwho-1686387

RESUMO

We investigated a COVID-19 outbreak at a fire station in Marseille, France. Confirmed cases were defined as individuals with positive SARS-CoV-2 reverse transcription (RT)-PCR and/or neutralising antibodies. All 85 firefighters at work during the outbreak period were included after questioning and sampled for RT-PCR and viral neutralisation assay. Twenty-three firefighters were confirmed positive, 19 of them were symptomatic, and four asymptomatic cases were confirmed by virus neutralisation. A total of 22 firefighters had specific neutralising antibodies against SARS-CoV-2. Neutralising antibodies were found in four asymptomatic and 18 symptomatic cases. Eleven symptomatic cases had high titres (≥ 1:80). The earliest detection of neutralising antibodies was 7 days after symptom onset, and 80% had neutralising antibodies 15 days after onset. One viral culture was positive 13 days after onset. The attack rate was 27%. We identified two introductions of the virus in this outbreak, through a presymptomatic and a paucisymptomatic case. Asymptomatic cases were not the source of a third generation of cases, although they worked without wearing a mask, indicating that asymptomatic cases did not play a significant role in this outbreak. Management and strategy based on early research of clinical signs associated with self-quarantine was effective.


Assuntos
COVID-19 , Bombeiros , Surtos de Doenças , França/epidemiologia , Humanos , SARS-CoV-2
3.
Transfus Med Hemother ; 395: 1-6, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: covidwho-1374001

RESUMO

BACKGROUND: Passive therapy with convalescent plasma (CP) could be an effective and safe treatment option in COVID-19 patients. Neutralizing antibodies present in CP generated in response to SARS-CoV-2 infection and directed against the receptor-binding domain of the spike protein are considered to play a major role in the viral clearance. CP infusion may also contribute to the modulation of the immune response through its immunomodulatory effect. We describe for the first time the effectiveness of a CP collection protocol from repeated donations in young patients. MATERIALS AND METHODS: We enrolled health service workers who experienced mild to moderate COVID-19 and from whom several donations have been collected. No minimal severity threshold and no biological cure criteria were required. Donors could return to a second plasma donation 14 days after the first donation. A minimal neutralizing antibody titer of 1:40 was considered for clinical use. RESULTS: Eighty-eight donors were included (median age 35 [28-48] years, 41 women), and 149 plasma products were collected. COVID-19 were mainly WHO stage 2 infections (96%). Among the 88 first donations, 76% had neutralizing antibody titers higher than or equal to 1:40. Eighty-eight percent of donors who came for a second donation had a neutralizing antibody titer of 1:40. Median durations were 15 (15-19) and 38 (33-46) days from the first to the second donation and from recovery to the second donation, respectively. Sixty-nine percent of donors who came for a third donation had a neutralizing antibody titer of 1:40. Median durations were 16 (13-37) and 54 (49-61) days from the second to the third donation and from recovery to the third donation, respectively. No significant difference was observed between the IgG ratio and the age of the donors or the time between recovery and donation. The average IgG ratio did not significantly vary between donations. When focused on repeated blood donors, no significant differences were observed either. CONCLUSION: The recruitment of young patients with a mild to moderate CO-VID-19 course is an efficient possibility to collect CP with a satisfactory level of neutralizing antibodies. Repeated donations are a well-tolerated and effective way of CP collection.

4.
Euro Surveill ; 26(27)2021 07.
Artigo em Inglês | MEDLINE | ID: covidwho-1304570

RESUMO

We compared the performance of SARS-CoV-2 neutralising antibody testing between 12 European laboratories involved in convalescent plasma trials. Raw titres differed almost 100-fold differences between laboratories when blind-testing 15 plasma samples. Calibration of titres in relation to the reference reagent and standard curve obtained by testing a dilution series reduced the inter-laboratory variability ca 10-fold. The harmonisation of neutralising antibody quantification is a vital step towards determining the protective and therapeutic levels of neutralising antibodies.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/terapia , Europa (Continente) , Humanos , Imunização Passiva , Soroterapia para COVID-19
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA